30
< 302299 >

Micromodul™ connectors, pitch 1.27 mm

Micromodul™ connector for direct mating, insulation displacement technology (IDT), with locking on printed circuit board by means of locking hooks and toes, with closed sides

Approvals: VDE, cULus
Data Sheet (PDF)

Technical Data

Environmental conditions

Temperature range: -40 °C/+130 °C  *1

1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card

Materials

Insulating body: PA GF, V-0 according to UL94  *1

Contact spring: CuSn, pre-nickel and tin-plated – 302299
CuSn, pre-nickel-plated, gold-plated in cotact area, tin-plated in insulation displacement area – 302299 V122

1) component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)

Mechanical data

Mating with: printed circuit board 1.6 ± 0.14 mm

Insertion force/contact: < 1.3 N

Withdrawal force/contact: > 0.3 N

Connectable conductors for IDT area

Construction: flat cable 1.27 mm LiYV

Section min.: AWG 28 (0.09 mm²)

Section max.: AWG 26 (0.14 mm²)

Insulation diameter: 1.0 mm

Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.

Electrical data (at Tamb 20 °C)

Contact resistance: ≤ 5 mΩ

Rated current: 1.2 A at Tamb 85 °C

Rated voltage: 125 V AC
40 V (VDE)
50 V AC (UL)

Harnessing Equipment

Approved Cables

Approved Cables for 302299 Download (PDF)

Conductor Insulation Manufacturer
Typ Cross Section
(mm²)
Construction Lenght of Lay
(mm)
Surface
finishing
Diameter
(mm)
Material Temp. Range
(°C)
Name Designation Description
302299 0,097 x Ø 0,127 mm ribbon cable8Sn0,93PVC+105Klasing50066xx
302299 0,097 x 0,127 mm ribbon cable< 6,8Sn0,93 ± 0,05TPE-S-40/+125Klasing5001218, (STL 901 12)FL-ET 1,27 10 x 0,09mm², (AWG28)
302299 0,097 x Ø 0,127 mm ribbon cable8.46Sn0.89PVC-20/+1053MSerie 3365/10AWG 28
302299 0,097 x Ø 0,127 mm ribbon cable9–11Sn0.9PVC+105LTKSK-2651-309AWG 28
302299 0,1418 x Ø 0,10 mm ribbon cable< 15,20-1,05PVC+70TKD Kaweflex8022041LIYCY SO 08022041 PVC
302299 AWG 26/0,147 x Ø 0,16 mm11–13Sn1,00 ± 0,05NHFR105LTKSK-10368-018UL-Style 10368 26 AWG 105C

Connector systems with insulation displacement and crimp technology require suitable cables and accurate processing. In order to assure safe function of the connectors they must be processed with Lumberg harnessing equipment (series 97), according to Lumberg processing instructions, using cables approved by Lumberg. Do not hesitate to contact us if you have any questions!

The cables listed here have been tested in the laboratory and have been approved suitable for the specified connector type. Lumberg cannot assume warranty for possible modifications on the part of the cable manufacturer. It is the user’s responsibility to ensure the compatibility of the chosen components and their appropriateness for the intended application.

11/2024

Downloads

Poles / Product Inquiry

Designation Poles PU
(pieces)
MDQ
(pieces)
RFQ
(pieces)
Request for quote
(notes)
Inventory
(pieces)
302299 0441,3001,300
302299 0661,3001,300
302299 0881,3001,300
Immediately available at

Lumberg, DE2,600

302299 10101,3001,300
Immediately available at

Lumberg, CN1,300

302299 12121,3001,300
302299 14141,3001,300
302299 16161,3001,300
302299 18181,3001,300
302299 20201,3001,300
302299 22221,3001,300
302299 04 V12241,3001,300
302299 06 V12261,3001,300
302299 08 V12281,3001,300
302299 10 V122101,3001,300
302299 12 V122121,3001,300
302299 14 V122141,3001,300
302299 16 V122161,3001,300
302299 18 V122181,3001,300
302299 20 V122201,3001,300
302299 22 V122221,3001,300

Product Inquiry