33
< 332100 >

RAST 1.5 connectors, pitch 1.5 mm

RAST 1.5 connector for direct and indirect mating, insulation displacement technology (IDT)

State: New
Data Sheet (PDF)

Technical Data

Environmental conditions

Temperature range: -40 °C/+130 °C  *1

1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card

Materials

Insulating body: PA GF, V-0 according to UL94  *1

Contact spring: CuSn, tin-plated

1) material halogen-free and ATO-free, component glow wire resistant (GWEPT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)

Mechanical data

Mating with: printed circuit board 1.5 ± 0.14 mm

Insertion force/contact: ≤ 2.0 N

Withdrawal force/contact: ≥ 0.3 N

Connectable conductors for IDT area

Construction: discrete conductor

Section min.: 0.22 mm²

Section max.: 0.22 mm²

Insulation diameter: ≤ 1.2 mm

Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.

Electrical data (at Tamb 20 °C)

Rated current: 3 A (Tamb 85 °C, VDE)

Rated voltage: 50 V

Harnessing Equipment

Approved Cables

Approved Cables for 332100 S00Download (PDF)

Conductor Insulation Manufacturer
Typ Cross Section
(mm²)
Construction Lenght of Lay
(mm)
Surface
finishing
Diameter
(mm)
Material Temp. Range
(°C)
Name Designation Description
332100 S000,227 x Ø 0,21 mm9-1,1 -1,2PVC-40/+105Leoni76783002#FLRY 0,22-A
332100 S000,227 x Ø 0,2 mm7–9-1,15 ± 0,05TPE-40/+125Leoni88260330#LI31Y 1x0,22 BL SKT 1,15
332100 S000,227 x Ø 0,2 mm9-1,15 ± 0,05TPE-30/+125OmerinQ0507001PLASTHERM 41 0,22mm²
332100 S000,227 x Ø 0,2 mm7–9-1,15 ± 0,05PVC-40/+70Leoni8800001NALIY 1X0,22 BL
332100 S000,227 x Ø 0,194 mm ± 0,0067–9-1,15 ± 0,05PVC-5/+90Leoni8800001MALiYW 1x0,22 BL
332100 S000,227 x Ø 0,2 mm9 -2,0-1,15 ± 0,05PVC-5/+105Leoni8900003IALiYW 1 x 0,22 mm² BL UL 11324
332100 S000,227 x Ø 0,21 mm16 ± 2-1,20 -0,1PE-40/+150Prysmian20273209FLR91X-A hffr 0,22 SW
332100 S000,237 x Ø 0,203 mmSn1,15 ± 0,05PVC-10/+80Medi122247UL/cUL-Style 1061/10002 AWG 24

Connector systems with insulation displacement and crimp technology require suitable cables and accurate processing. In order to assure safe function of the connectors they must be processed with Lumberg harnessing equipment (series 97), according to Lumberg processing instructions, using cables approved by Lumberg. Do not hesitate to contact us if you have any questions!

The cables listed here have been tested in the laboratory and have been approved suitable for the specified connector type. Lumberg cannot assume warranty for possible modifications on the part of the cable manufacturer. It is the user’s responsibility to ensure the compatibility of the chosen components and their appropriateness for the intended application.

11/2024

Downloads

Poles / Product Inquiry

Designation Poles PU
(pieces)
MDQ
(pieces)
RFQ
(pieces)
Request for quote
(notes)
332100 022990
332100 033738
332100 044588
332100 055492
332100 066420
332100 077366
332100 088324
332100 099288
332100 1010264
332100 1111240
332100 1212222