35
< 3510-1 >

RAST 2.5 connectors, pitch 2.5/5.0 mm

RAST 2.5 connector for direct mating, insulation displacement technology (IDT), alternatively with or without keying rib and closed sides, for ribbon cable, daisy chain possible
contact pitch 2.5 mm

Approvals: cULus
Data Sheet (PDF)

Technical Data

Environmental conditions

Temperature range: -40 °C/+130 °C  *1

1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card

Materials

Insulating body: PBT, V-0 according to UL94 – 3510-1 (S...V...)
PA, V-2 according to UL94 – 3510-1 M12(S...V...)  *1

Contact spring: CuSn, tin-plated – 3510-1 (M...S...)
CuSn, tin-plated (Sn/Ag), 2-9 poles – 3510-1 (M...S...)V03
CuSn, pre-nickel and gold-plated – 3510-1 (M...S...)V102

1) M12: component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)

Mechanical data

Mating with: printed circuit board 1.5 ± 0.14 mm

Insertion force/contact: ≤ 4,0 N

Withdrawal force/contact: ≥ 0,5 N

Connectable conductors for IDT area

Construction: flat cable 2.5 mm

Section min.: 0,14 mm²

Section max.: 0,38 mm²

Insulation diameter: ≤ 1,6 mm

Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.

Electrical data (at Tamb 20 °C)

Contact resistance: ≤ 5 mΩ

Rated current: 4 A (Tamb 60 °C)
2 A (Tamb 100 °C)

Rated voltage: 32 V AC

Harnessing Equipment

Approved Cables

Approved Cables for 3510-1 Download (PDF)

Conductor Insulation Manufacturer
Typ Cross Section
(mm²)
Construction Lenght of Lay
(mm)
Surface
finishing
Diameter
(mm)
Material Temp. Range
(°C)
Name Designation Description
3510-1 0,227 x Ø 0,20 mm
ribbon cable
18Sn1,35 ± 0,05PVC+105Klasing50154xx
3510-1 0,227 x Ø 0,20 mm ribbon cable18Sn1,4+0,05/-0,1PVC+70Monette19.302X2,5FL - LiYV
3510-1 0,227 x Ø 0,20 mm ribbon cable18Sn1,4+0,05/-0,1PVC+105Monette19.312X2,5FL - LiYV
3510-1 0,227 x Ø 0,20 mm
ribbon cable
8,9Sn1,4PVC+105Medi524703… ...FBL LIY/ZGL x AWG 24
3510-1 0,227 x 0,20 mm
ribbon cable
< 18Sn1,35 ± 0,05PVC-30/+105Klasing2,5 FL-LiYV 7 x 0,22 mm² ZG, STL 902 067 x 0,22 mm², grau
3510-1 0,237 x Ø 0,203 mm
ribbon cable
16Sn1,35 ± 0,05PVC+105Klasing50253xxFL-ZGL XXx0,23 1,35 R2,5
3510-1 0,2311 x Ø 0,16 mm
ribbon cable
16Sn1,4 ± 0,1PVC105LTKSK-2651-202PVC-isolierte Flachbandleitung 24 AWG
3510-1 0,357 x Ø 0,24517 +/- 1,7Sn1,4 ± 0,05PVC-15/+70VercaviHP 1035----S5FR2 1 x 0,35mm²

Approved Cables for 3510-1 S01

Conductor Insulation Manufacturer
Typ Cross Section
(mm²)
Construction Lenght of Lay
(mm)
Surface
finishing
Diameter
(mm)
Material Temp. Range
(°C)
Name Designation Description
3510-1 S010,357 x 0,241 mm15Sn1,35 ± 0,05PVC70Prysmian20149750LiY Sn 1 x 0,35mm²

Approved Cables for 3510-1 S02

Conductor Insulation Manufacturer
Typ Cross Section
(mm²)
Construction Lenght of Lay
(mm)
Surface
finishing
Diameter
(mm)
Material Temp. Range
(°C)
Name Designation Description
3510-1 S02AWG 241 x Ø 0,51 mm-SnPE-40/+105SumidaFxx-Pxxx-002Panta-Fix Jumper

Approved Cables for 3510-1 S03

Conductor Insulation Manufacturer
Typ Cross Section
(mm²)
Construction Lenght of Lay
(mm)
Surface
finishing
Diameter
(mm)
Material Temp. Range
(°C)
Name Designation Description
3510-1 S030,347 x 0,26 mm15Sn1,4 ± 0,1PVC-40/+105KBE5000340110250ALiY 0,34 mm²
3510-1 S030,3417 x 0,16 mm18Sn1,58 ± 0,05PVC80Leoni10.097.999F5007AWG 22
3510-1 S030,357 x 0,25 mm5-10Sn1,25 ± 0,03PVC-40/+70Leoni88030810#LiY 0,35 mm²
3510-1 S030,357 x Ø 0,245 mm16.8Sn1,35 +0,1/-0,05PVC-10/+105VercaviHH1035----SFFR 3/2 1 x 0.35mm²
3510-1 S030,3557 x Ø 0,245 mm17 ± 10 %Sn1,55 +0,02/-0,04PCV-25/+105KBE4100225110245KAWG 22 Style 1569

Connector systems with insulation displacement and crimp technology require suitable cables and accurate processing. In order to assure safe function of the connectors they must be processed with Lumberg harnessing equipment (series 97), according to Lumberg processing instructions, using cables approved by Lumberg. Do not hesitate to contact us if you have any questions!

The cables listed here have been tested in the laboratory and have been approved suitable for the specified connector type. Lumberg cannot assume warranty for possible modifications on the part of the cable manufacturer. It is the user’s responsibility to ensure the compatibility of the chosen components and their appropriateness for the intended application.

04/2024

Downloads

Poles / Product Inquiry

Designation Poles PU
(pieces)
MDQ
(pieces)
RFQ
(pieces)
Request for quote
(notes)
3510-1 0224,9504,950
3510-1 0333,6003,600
3510-1 0442,7002,700
3510-1 0552,2502,250
3510-1 0661,8003,600
3510-1 0771,8003,600
3510-1 0881,3502,700
3510-1 0991,3502,700
3510-1 10101,3502,700

Product Inquiry

Branch
Name / Company
Address
Contact