36
< 3628-1 >

RAST 5 connectors, pitch 5.0 mm

RAST 5 chassis connector for indirect mating, insulation displacement technology (IDT), with interior locking, for use in a higher temperature range

Approvals: VDE
Data Sheet (PDF)

Technical Data

Environmental conditions

Temperature range: -40 °C/+150 °C – 3628-1 M05(S03)

Materials

Insulating body: PA, V-2 according to UL94 – 3528-1 M05(S03)

Contact spring: Cu alloy, silver-plated

Mechanical data

Mating with: tab contact 6.3 mm x 0.8 mm according to DIN 46244

Insertion force/contact: ≤ 4,0 N

Withdrawal force/contact: ≥ 1,0 N

Connectable conductors for IDT area

Construction: discrete conductor, notched flat cable 5.0 mm

Section min.: 0,75 mm²

Section max.: 1 mm²

Insulation diameter: ≤ 3,0 mm

Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.

Electrical data (at Tamb 20 °C)

Contact resistance: ≤ 5 mΩ

Rated current: 10.5 A (1.0 mm², Tamb 120 °C)

Rated voltage: 250 V AC

Counterparts

Harnessing Equipment

Approved Cables

Approved Cables for 3628-1 S03Download (PDF)

Conductor Insulation Manufacturer
Typ Cross Section
(mm²)
Construction Lenght of Lay
(mm)
Surface
finishing
Diameter
(mm)
Material Temp. Range
(°C)
Name Designation Description
3628-1 S030,7524 x Ø 0,21 mm30Sn2,3 +0,05/-0,10PVC-15/+90KBE35007500101905H05V2-K 0,75²
3628-1 S03119 x Ø 0,26 mm10Sn2,5 ± 0,1Silicone+180Cet999010502016A
3628-1 S03119 x Ø 0,26 mm10Sn2,5 ± 0,1Silicone+180Cet999010504006A
3628-1 S03119 x Ø 0,26 mm10Sn2,5 ± 0,1Silicone+180Cet999010505013A
3628-1 S03119 x Ø 0,26 mm10Sn2,5 ± 0,1Silicone+180Cet999010509006A
3628-1 S03119 x Ø 0,26 mm10 ± 2Sn2.5Silicone180BLF51/ 2843 ... 53P7/01 Silicone 1,00 mm²

Connector systems with insulation displacement and crimp technology require suitable cables and accurate processing. In order to assure safe function of the connectors they must be processed with Lumberg harnessing equipment (series 97), according to Lumberg processing instructions, using cables approved by Lumberg. Do not hesitate to contact us if you have any questions!

The cables listed here have been tested in the laboratory and have been approved suitable for the specified connector type. Lumberg cannot assume warranty for possible modifications on the part of the cable manufacturer. It is the user’s responsibility to ensure the compatibility of the chosen components and their appropriateness for the intended application.