73
SmartSKEDD™ direct connectors, pitch 2.5/5.0 mm
SmartSKEDD direct connector, insulation displacement technology (IDT), with keying pins, positioning spigot and locking on the printed circuit board
contact pitch 2.5 mm
Approvals: | VDE |
Technical Data
Environmental conditions
Temperature range: -40 °C/+130 °C *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PBT, V-0 nach UL94 *1
Contact spring: CuSn, silver-plated
1) material halogen-free, GWFI 850 °C (0,40 mm), GWIT 775 °C (0,40 mm)
Mechanical data
Mating with: printed circuit board 1.6 ± 0.14 mm
Insertion force/contact: ≤ 3 N
Withdrawal force/contact: ≥ 3 N
Retaining force/locking: ≥ 50 N
Connectable conductors for IDT area
Construction: discrete conductor, notched flat cable 2.5 mm
Section min.: 0,22 mm²
Section max.: 0,38 mm²
Insulation diameter: ≤ 1.6 mm
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 4 A (Tamb 85 °C)
Rated voltage: 50 V AC *1
1) according to IEC 60664/DIN EN 60664, CTI UL classification according to ANSI/UL 746A
Harnessing Equipment
HA7335e
Semiautomatic harnessing machine for termination of SmartSKEDD connectors in insulation displacement technology (IDT), small base machine, limited upgrading possible
HA7335e-CA
Semiautomatic harnessing machine for termination of SmartSKEDD connectors in insulation displacement technology (IDT), small base machine with integrated cable color detection, limited upgrading possible
Approved Cables
Approved Cables for 733520 Download (PDF)
Conductor | Insulation | Manufacturer | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Typ | Cross Section (mm²) |
Construction | Lenght of Lay (mm) |
Surface finishing |
Diameter (mm) |
Material | Temp. Range (°C) |
Name | Designation | Description |
733520 | 0,25 | 7 x Ø 0,2 mm | 12 | Sn | 1,42–1,48 | PVC | -15/+70 | Prysmian | 20143789 | Protodur LiY 0,25 mm² |
733520 | 0,35 | 7 x Ø 0,26 mm | 25 | - | 1,30 ± 0,1 | TPE-E | -40/+150 | Gebauer & Griller | 68534 | FLR13Y-A 0,35 mm² |
733520 | 0,35 | 12 x Ø 0,21 mm | 25 | Sn | 1,40 -0,2 | PVC | -40/+105 | KBE | 1000350110195A | FLRY 0,35 mm² |
733520 | 0,36 | 12 x Ø 0,194 mm | 15 | - | 1,40 ± 0,05 | PVC | -5/+70 | Leoni | 88200132Z | LiY 1 x 0,38 mm² BL |
733520 | 0,38 | 12 x Ø 0,194 mm ± 0,006 | 15 | - | 1,40 ± 0,05 | PVC | -15/+70 | KBE | 5000380120198E | LiY 0,38 mm² |
Connector systems with insulation displacement and crimp technology require suitable cables and accurate processing. In order to assure safe function of the connectors they must be processed with Lumberg harnessing equipment (series 97), according to Lumberg processing instructions, using cables approved by Lumberg. Do not hesitate to contact us if you have any questions!
The cables listed here have been tested in the laboratory and have been approved suitable for the specified connector type. Lumberg cannot assume warranty for possible modifications on the part of the cable manufacturer. It is the user’s responsibility to ensure the compatibility of the chosen components and their appropriateness for the intended application.