30
Micromodul™ connectors, pitch 1.27 mm
Micromodul™ connector for indirect mating, insulation displacement technology (IDT), with lock MICA: loose, on reel
Approvals: | VDE, cULus |
Technical Data
Environmental conditions
Temperature range: -40 °C/+120 °C *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PBT GF, V-0 according to UL94
Contact spring: CuSn, tin-plated – MICA
CuSn, gold-plated in contact area, tin-plated in insulation displacement area – MICA SEL 0,8 AU
Mechanical data
Insertion force/contact: ≤ 1.5 N
Withdrawal force/contact: > 0.4 N
Connectable conductors for IDT area
Construction: flat cable 1.27 mm LiYV
Section min.: AWG 28 (0.09 mm²)
Section max.: AWG 26 (0.14 mm²)
Insulation diameter: 1.0 mm
Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 10 mΩ
Rated current: 1.2 A
Rated voltage: 32 V AC
(250 V AC without consideration of creepage and clearance distances according to IEC 60664/DIN EN 60664)
Counterparts
MICS
Micromodul™ tab header, upright, with retaining hooks, solder contacts dual row staggered
MICS-D
Micromodul™ tab header, upright, without retaining hooks, solder contacts dual row parallel
MICSW
Micromodul™ tab header, angular, solder contacts dual row staggered
MICS/SMD
Micromodul™ tab header, upright, in surface mount technology (SMT), solder contacts dual row staggered, with press-fit spigots, in bulk, with retaining hooks
MICS/SMD RP
Micromodul™ tab header, upright, in surface mount technology (SMT), solder contacts dual row staggered, with press-fit spigots, on reel, with pick-and-place top
Accessory
Harnessing Equipment
HA30e-R
Semiautomatic harnessing machine for termination of Micromodul™ connectors in insulation displacement technology (IDT)
HA3...e
Processing modules for termination of connectors in insulation displacement technology (IDT), for use with suitable fully automatic harnessing machines
VARICON 1000-Eco
Fully automatic harnessing machine for termination of Micromodul™ connectors in insulation displacement technology (IDT)
VARICON 1000
Fully automatic harnessing machine for termination of Micromodul™ connectors in insulation displacement technology (IDT)
Approved Cables
Approved Cables for MICA VP3 Download (PDF)
Conductor | Insulation | Manufacturer | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Typ | Cross Section (mm²) |
Construction | Lenght of Lay (mm) |
Surface finishing |
Diameter (mm) |
Material | Temp. Range (°C) |
Name | Designation | Description |
MICA VP3 | 0,08 | 7 x 0,12 mm +/-0,005 ribbon cable | 9.41 | Sn | 0,9 +/- 0,08 | PVC | 105 | Datafield WenChang | FLC-10647-14GY WCH P/N UL 2651 | UL 2651 28 AWG*14P PH:1.27 mm |
MICA VP3 | 0,08 | 1 x Ø 0,32 mm ribbon cable | Sn | 0,93 ± 0,05 | PVC | +105 | Klasing | 5009240 | FD 9 x 0,32/0,93 R1,27 | |
MICA VP3 | 0,08 | 1 x Ø 0,32 mm ribbon cable | Sn | 0,75 ± 0,1 | PE | +130 | Sumida | Bxx-Pxxx-A-001 | Panta-Fix Jumper | |
MICA VP3 | 0,087 | 7 x Ø 0,127 mm ribbon cable | 9,41 | Sn | 0,89 ± 0,10 | PVC | +105 | Baohing | C1012217 | UL2651 28 AWGXnF |
MICA VP3 | 0,09 | 19 x Ø 0,079 ribbon cable | 6,45 | Sn | 0,89 | PVC | -20/+105 | 3M | 3539-Series, AWG28 | Medium Flex Life Cable,1,27mm, AWG28 |
MICA VP3 | 0,09 | 7 x Ø 0,127 mm ribbon cable | 8.46 | Sn | 0.89 | PVC | -20/+105 | 3M | Serie 3365/10 | AWG 28 |
MICA VP3 | 0,09 | 7 x Ø 0,127 mmribbon cable | 8 | Sn | 0,93 ± 0,05 | PVC lead-free | +105 | Draka | BMW 8 380 723.9 | FLRZYW-A xAWG28/7/0,93 |
MICA VP3 | 0,09 | 7 x Ø 0,12 mm ribbon cable | 12,7 | Sn | 0,9 ± 0,05 | PVC | +105 | Hung Fu | HF 9-64 | HF1,27Centers PVC/ 28AWG |
MICA VP3 | 0,09 | 19 x Ø 0,08 mmribbon cable | 5 | Sn | 0,89 ± 0,13 | PVC | +105 | JST | JFCR 28L-10HF127 | JFCR 28L-xxHF 127 |
MICA VP3 | 0,09 | 19 x 0,079 mm ribbon cable | 5 | Sn | 0,93 +/- 0,05 | PVC | -10/+105 | Klasing | 5002208 | Flachbandleitung FL-f |
MICA VP3 | 0,09 | 7 x Ø 0,127 mm ribbon cable | 8 | Sn | 0,93 | PVC | +105 | Klasing | 50066xx | |
MICA VP3 | 0,09 | 7 x Ø 0,12 mm ribbon cable | 7,6 | Sn | 0,93 ± 0,05 | Polyolefin | +105 | Klasing | 50532xx | |
MICA VP3 | 0,09 | 7 x Ø 0,127 mm ribbon cable | 7,6 | Sn | 0,89 | PVC | +105 | Klasing | 50067xx | FL-ZGL XXx0,09/0,93 |
MICA VP3 | 0,09 | 7 x Ø 0,127 mm ribbon cable | 9,1 | Sn | 0,9 ± 0,1 | PVC | +105 | Lian Yu | LY 881004 | 1,27mm FLAT CABLE AWG 28 |
MICA VP3 | 0,09 | 7 x Ø 0,127 mm ribbon cable | 7,6 | Sn | 0,89 ± 0,08 | PVC | +105 | Tyco | 1-971111-4 | UL-Style 2651/ CSA AWM IA |
MICA VP3 | 0,14 | 7 x Ø 0,16 mm ribbon cable | 7,6 | Sn | 1 ± 0,05 | PVC | +105 | Klasing | 50277xx | |
MICA VP3 | 0,14 | 7 x Ø 0,16 mm ribbon cable | 8 | Sn | 1,00 ± 0,05 | PVC | -10/+80 | Medi | 122267 | UL/cUL Style 1061/10002 AWG 26 |
MICA VP3 | 0,14 | 19 x Ø 0,1 mm | 27 | Sn | 1,10 ± 0,05 | mPPE | -40/+80 | Kabeltronik | 216042600 | PUR-tronic D-UL-Flex FRNC UL AWM 21223/ 11028 |
MICA VP3 | 0,15 | 19 x Ø 0,1 mm ribbon cable | 27 | Sn | 1,10 ± 0,05 | PPE | -20/+80 | Kabeltronik | 215042600 | AWG 26 |
MICA VP3 | AWG 28 | 1 x Ø 0,3 mm foil cable | - | Sn | Nomex | -40/+125 | Sumida | Bxx-Nxxx-x-8,5 | Panta-Fix Jumper |
Connector systems with insulation displacement and crimp technology require suitable cables and accurate processing. In order to assure safe function of the connectors they must be processed with Lumberg harnessing equipment (series 97), according to Lumberg processing instructions, using cables approved by Lumberg. Do not hesitate to contact us if you have any questions!
The cables listed here have been tested in the laboratory and have been approved suitable for the specified connector type. Lumberg cannot assume warranty for possible modifications on the part of the cable manufacturer. It is the user’s responsibility to ensure the compatibility of the chosen components and their appropriateness for the intended application.
04/2024